High-precision
angle measurement
High-precision in linearity and reproducibility in angle measurement
is achieved by a unique angle measuring mechanism and high-precision
mechanism.
|
 |
Stable
performance over long time
The mechanism units feature high stiffness and durability and parts
are processed sufficiently to remove internal stresses on the material
level, assuring stable performance over a long time.
|
 |
Unique
X-ray profile peak detection function
A unique X-ray profile peak detection function that fully utilizes
a statistic-processing technology is used, assuring high-precision
and stable angle measuring performance.
|
 |
High-speed
measurement
The 2- and 4-orientation measuring functions reduce measuring time
to about half compared with 4-orientation measurement. (Model SU-001
does not have this feature.)
2-orientation measurement calculates X and Y
inclinations of crystal orientation by means of a strict solution
utilizing spherical geometry. For this reason, calculations can be
made at the same accuracy as that in 4-orientation measurement.(Provisional
Patent Publication 1999-64252. Patent applied for)
|
 |
Unique
X-ray dose measuring system
The X-ray dose measuring system reduces error causes such as scattering
using a pulse height analyzer and measures by selecting the characteristic
X-rays of Cu, allowing high-precision measurement.
|
 |
High-sensitivity
detector is used
The X-ray tube and detector, which are the most important components,
are manufactured by Toshiba. The detector has an extremely high sensitivity
to the X-ray (K
of Cu) to be detected. Because this detector is a proportional counter,
the detection sensitivity of it relative to the incident position
and direction of X-rays fluctuates less, allowing stable measurement
against fluctuations of the inclination angle of a crystal face.
|
 |
Long
life
The X-ray tube is a life component that greatly affects the running
cost. A large-capacity X-ray tube is used. A long life is achieved
by lowering de-rating. (De-rating is 60% in tube voltage and 80% in
tube current)
|
 |
Recording
in variety of media
Measurement data can be output and recorded in the following media
(Model SU-001 does not have this feature.):
Console, printer, HDD, FD and data transfer (option)
|
 |
Operability
A function that allows manual operation for each unit function is
provided for ease of adjustment and function checking. Parameters
for internal arithmetic processing and other data are protected by
a password to restrict operation to specified persons only. A personal
computer for factory automation purposes is used to ensure reliability
over many hours' operation.
|
 |
High
safety-factor
The unit comes complete with measures to prevent X-ray exposure and
for safety.
The X-ray exposure dose can be limited as the unit does not emit X-rays
except during angle measurement.
|